Journal of Laboratory Medicine and Quality Assurance ; : 75-81, 2019.
Article in Korean | WPRIM | ID: wpr-765642

ABSTRACT

In 2018, external quality assessment trials for urinalysis and fecal occult blood (FOB) were performed using 1,590 participants. Urine chemistry tests were performed thrice while urine sediment and FOB tests twice. Urine chemistry tests comprised of pH, protein, glucose, ketone body, bilirubin, blood, urobilinogen, nitrite, leukocyte, and specific gravity analyses. The results of urine chemistry and specific gravity tests showed accuracy rates >95%, except for the pH test. The accuracy rate of urine sediments was low, especially for atypical calcium oxalate crystal and red blood cell cast. In the FOB quality test, reagents showed accuracy rates >90%, except for SD and GC Genedia FOB reagents. In the FOB quantitative test, Alfresa NS-Plus C instrument showed falsely high values in the FOB negative specimens.


Subject(s)
Bilirubin , Calcium Oxalate , Chemistry , Erythrocytes , Glucose , Hydrogen-Ion Concentration , Indicators and Reagents , Leukocytes , Occult Blood , Quality Control , Specific Gravity , Urinalysis , Urobilinogen
2.
Journal of Laboratory Medicine and Quality Assurance ; : 128-135, 2018.
Article in Korean | WPRIM | ID: wpr-716938

ABSTRACT

In 2017, external quality assessment trials for urinalysis and fecal occult blood (FOB) were performed with 1,544 participants. Urine chemistry tests were performed three times and urine sediment and FOB tests were evaluated 2 times. Urine chemistry tests consisted of pH, protein, glucose, ketone, bilirubin, blood, urobilinogen, nitrite, leukocyte, and specific gravity analyses. The results of the urine chemistry and specific gravity tests showed accuracy rates >95%. The accuracy rate of urine sediments was low, especially for fat droplets and atypical uric acid crystals. In the FOB quality test, all reagents showed accuracy rates >82%, which suggested the persistent improvement of false-positive reactions. In the FOB quantitative test, discrepant results depending on the instrument used were observed. To compensate for the result differences caused by the amounts of stool samples, the results should be reported using another unit (µg/g of stool).


Subject(s)
Bilirubin , Chemistry , Glucose , Hydrogen-Ion Concentration , Indicators and Reagents , Korea , Leukocytes , Occult Blood , Quality Control , Specific Gravity , Uric Acid , Urinalysis , Urobilinogen
3.
Journal of Laboratory Medicine and Quality Assurance ; : 117-123, 2017.
Article in Korean | WPRIM | ID: wpr-100913

ABSTRACT

In 2016, external quality assessment trials for urinalysis and faecal occult blood (FOB) were performed with 1,487 participants in Korea. Urine chemistry and FOB tests were performed three and two times, respectively, whereas urine sediment was evaluated once using photography. Urine chemistry tests consisted of pH, protein, glucose, ketone, bilirubin, blood, urobilinogen, and nitrite levels; leukocyte count; specific gravity. The results of the urine chemistry and specific gravity tests showed accuracy rates of >95%. The accuracy rate of urine sediments was low, especially that for transitional epithelial cells and atypical crystals. In the FOB quality test, all reagents showed accuracy rates of >90%, which suggested the improvement of false-positive reaction. In the FOB quantitative test, discrepant results depending on the instrument used was observed. To compensate for the result differences caused by the stool samples, the results should be reported using another unit (µg/g of stool).


Subject(s)
Bilirubin , Chemistry , Epithelial Cells , Glucose , Hydrogen-Ion Concentration , Indicators and Reagents , Korea , Leukocyte Count , Occult Blood , Photography , Specific Gravity , Urinalysis , Urobilinogen